In all areas of special flood hazards where base flood elevation data has been provided as set forth in Section 15.44.030 or Section 15.44.060 B, the following provisions are required.

A. Residential Construction.

1. New construction and substantial improvement of any residential structure shall have the lowest floor, including basement, elevated to or above base flood elevation.

2. Fully enclosed areas below the lowest floor that are subject to flooding are prohibited, or shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of flood waters. Designs for meeting these requirements must either be certified by a registered professional engineer or architect or must meet or exceed the following minimum criteria:

a. A minimum of two openings have a total new area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided;

b. The bottom of all openings shall be no higher than one foot above grade;

c. Openings may be equipped with screens, louvers, or other coverings or devices; provided that they permit the automatic entry and exit of floodwaters.

B. Nonresidential Construction.

1. New construction and substantial improvement of any commercial, industrial or other nonresidential structure shall either have the lowest floor, including basement, elevated to the level of the base flood elevation; or, together with attendant utility and sanitary facilities, shall:

a. Be flood proofed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water;

b. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy;

c. Be certified by a registered professional engineer or architect that the design and methods of construction are in accordance with accepted standards of practice for meeting provisions of this subsection based on their development and/or review of the structural design, specifications and plans. Such certifications shall be provided to the official as set forth in Section 15.44.060(B).

2. Non-residential structures that are elevated, not flood proofed, must meet the same standards for space below the lowest floor as described in subsection A of this section.

3. Applicants flood proofing nonresidential buildings shall be notified that flood insurance premiums will be based on rates that are one foot below the flood proofed level (e.g., a building constructed to the base flood level will be rated as one foot below that level).

C. Manufactured Homes. All manufactured homes to be placed or substantially improved within Zones Al 30, AH, and AE shall be elevated on a permanent foundation such that the lowest floor of the manufactured home is at or above the base flood elevation and be securely anchored to an adequately anchored foundation system in accordance with the provisions of Section 15.44.070 B2. (Ord. 1610, 1989; Ord. 1490, 1981)