A. Specific Planned Development Approval Criteria. The following approval criteria shall apply to the planned development:

1. All the provisions of the land division provisions, Title 16, shall be met.

2. Except as noted, the Conditional Use Decision Criteria (Chapter 17.06) shall be the approval criteria. A Planned Development need not meet these requirements where a development plan provides alternative designs and methods, if acceptable to the Planning Commission, that promote the purpose of this section. In each case, the applicant must provide findings to justify the modification of the approval criteria in the Conditional Use chapter (Chapter 17.06). The developer may choose to provide, or the Commission may require, additional amenities, landscaping, or tree planting.

3. A minimum of thirty (30%) percent of a Planned Development site area shall be reserved as common open space. The thirty percent (30%) open space requirement shall be exempt in the Central Business district and the Heights Business District. Open space means an area intended for common use either privately owned and maintained or dedicated to the City. This area shall be designated for outdoor living and recreation or the retention of an area in its natural state. Open space may include swimming pools, recreation courts, patios, open landscaped areas, or greenbelts with pedestrian, equestrian, and bicycle trails. Open space does not include off-street parking or loading areas.

4. Unless authorized below, residential density shall be governed by the density established in the underlying zoning district. The Planning Commission may further authorize a residential density bonus not to exceed thirty-three (33%) percent as an incentive to enhance the architectural character of the development. The degree of distinctiveness and the desirability of variation achieved shall govern the amount of density increase that the Planning Commission may approve according to the following:

a. A maximum of ten (10%) percent is allowed for the inclusion of at least six (6) of the architectural features listed below on all elevations, as appropriate for the proposed building type and style. Features may vary on rear/side/front elevations where appropriate.

b. A maximum of twenty (20%) percent is allowed for the inclusion of at least nine (9) of the architectural features listed below on all elevations, as appropriate for the proposed building type and style. Features may vary on rear/side/front elevations where appropriate.

c. A maximum of thirty-three (33%) percent is allowed for the inclusion of at least twelve (12) of the architectural features listed below on all elevations, as appropriate for the proposed building type and style. Features may vary on rear/side/front elevations where appropriate. See the following Diagram “C” for examples of architectural features.

1. Dormers

2. Gables

3. Recessed entries

4. Covered porch entries

5. Cupolas or towers

6. Pillars or posts

7. Eaves (min. 18-inch projection)

8. Off-sets in building face or roof (minimum 16 inches)

9. Window trim (minimum 4-inches wide)

10. Bay windows

11. Balconies

12. Decorative patterns on exterior finish (e.g., scales/shingles, wainscoting, ornamentation, and similar features)

13. Decorative cornices and roof lines (e.g., for flat roofs)

14. Façade articulation (siding materials should only be changed along horizontal lines)

15. High quality exterior siding material. High quality means that there should be a single, clearly dominant material for all exterior walls. Brick, stucco, and stone front facades shall return at least eighteen (18) inches around sidewalls. Lap siding and shingles shall be exposed a maximum of five (5) inches. Heavier materials shall appear only below lighter appearing materials.

16. An alternative feature providing visual relief, similar to options (1)-(15) above.

5. The following criteria shall apply to all Planned Developments unless otherwise specified as applicable only to certain specific uses:

a. Relationship to the natural and physical environment:

1. The streets, buildings, and other site elements shall be designed and located to preserve the existing trees, topography, and natural drainage to the greatest degree possible.

2. Structures located on the site shall not be in areas subject to ground slumping and sliding.

3. There shall be adequate distance between on-site buildings and other on-site and off-site buildings on adjoining properties to provide for adequate light and air circulation and for fire protection.

4. The structures shall be oriented with consideration for the sun and wind directions, where possible.

b. Private outdoor area – multi-family use:

1. Each ground-level residential dwelling unit shall have an outdoor private area (patio, terrace, porch) of not less than forty-eight (48) square feet.

2. Wherever possible, private outdoor open spaces should be oriented toward the sun.

3. Private outdoor spaces shall be screened or designed to provide privacy for the use of the space.

c. Shared outdoor recreation areas – multi-family use:

1. Each multiple-dwelling development shall incorporate shared usable outdoor recreation areas within the development plan as follows:

a. Studio units up to and including two (2) bedroom units shall provide 200 square feet per unit.

b. Three or more bedroom units shall provide 300 square feet per unit.

2. Shared outdoor recreation space shall be readily observable from adjacent units for reasons of crime prevention and safety.

3. The required recreation space may be provided as follows:

All outdoor space;

a. Part outdoor space and part indoor space (e.g. an outdoor tennis court and indoor recreation room);

b. All public or common space; or

c. Part common space and part private (e.g. an outdoor tennis court, indoor recreation room, and balconies on each unit).

i. Where balconies are added to units, the balconies shall not be less than forty-eight (48) square feet.

d. Parking: All of the required off-street parking spaces may be provided in one or more common parking lots within the Planned Development.

e. Drainage: All drainage provisions shall be subject to review and approval by the City Engineer and shall comply with all applicable provisions of the ORS and HRMC.

f. Floodplain dedication: Where landfill and/or development is allowed within or adjacent to the one hundred (100) year floodplain, the City shall require consideration of the dedication of sufficient open land area for a greenway adjoining and within the floodplain. This area shall include portions of a suitable elevation for the construction of a pedestrian/bicycle pathway within the floodplain in accordance with the adopted pedestrian bicycle pathway plan.

B. Additional Criteria for Commercial and Industrial Development. In addition to the specific Planned Development approval criteria above, Planned Developments with commercial and industrial uses shall meet the following criteria:

1. Commercial and industrial uses that abut existing residential zones shall be located on the site or be designed in a manner, to the maximum degree possible, to protect the private areas on the adjoining properties from view and noise.

2. Commercial projects are encouraged to include housing as a secondary use, as appropriate.

3. All commercial buildings shall contribute to the storefront character and visual relatedness of surrounding buildings. This criterion is met by providing all of the architectural features listed below along the front building elevation (i.e., facing the street), as applicable.

1. Corner building entrances on corner lots. Alternatively, a building entrance may be located away from the corner when the building corner is beveled or incorporates other detailing to reduce the angular appearance of the building at the street corner.

2. Regularly spaced and similar-shaped windows with window hoods or trim (all building stories).

3. Large display windows on the ground-floor (nonresidential uses only). Display windows shall be framed by bulkheads, piers, and a storefront cornice (e.g., separates ground-floor from second story, as shown below).

4. Decorative cornice at top of building (flat roof), or eaves provided with pitched roof.

[Note: the example shown below (Diagram “D” – Building Design Elements) is meant to illustrate required building design elements and should not be interpreted as a required architectural style.

C. Industrial developments shall be oriented on the site to minimize adverse impacts (e.g. noise glare, smoke, dust, exhaust, vibration, etc.) The following standards shall apply:

1. Mechanical equipment, lights, emissions, shipping/receiving areas, and other components of an industrial use that are outside enclosed buildings shall be located away from residential areas, schools, parks, and other non-industrial areas to the maximum extent practicable; and

2. A landscape buffer, or other visual or sound barrier (fence, wall, landscaping, or combination thereof), maybe required to mitigate adverse impacts that cannot be avoided through building orientation standards alone.

D. Industrial buildings oriented to the street shall have architectural features such as windows, pedestrian entrances, building off-sets, projections, detailing, change in materials, or similar features to break up and articulate large building surfaces and volumes.

E. Industrial buildings shall have pedestrian-scale building entrances by including recessed entries, canopies, and/or similar features.